HONEYWELL C7735A1000 Discharge AIR Temperature Sensor …

Honeywell C7735A1000 The C7735A1000 Discharge Air Temperature Sensor (DATS) is a ductmounted temperature probe that provides capacity control of heating and cooling equipment. The DATS is used only with zoning solutions, including TZ3, MABS EZ2 and MABS EZ4, and EMM 3 and EMM3U control panels. Mounted in the supply air duct, the DATS senses the delivered air temperature and …


69219801 TrueZONE Zone Panel Professional Installation ...

Sensor * DATS C7735A1000* Wired Outdoor Air Temperature Sensor C7089U1006 (hard wired) Wireless Outdoor Air Temperature Sensor C7089R1013 (wireless) Wireless Adapter THM4000R1000 TAZ4 TotalZone® AddAZoneTM Control Panel SDCR Slave Damper Control Relay Wireless Remote Control REM5000R1001 * Included in HZ432K kit. Installation Guide 692 98—0 2 MOuNTiNg Mount …


TZ4 TotalZone® Zone Control Panel

Discharge Air Temperature Sensor (C7735A1000); DATS, DATS. ZoneALone: OC, OC. Outdoor Temperature: OT, OT. Transformer 1: R (hot), C (common). Transformer 2: T1 (hot), T2 (common). Equipment: RcRh, W1/E, W2, W3/AUX Y1, Y2, G, O/B. Thermostats (See Table 1): Most conventional fourwire (R,W,Y,G) thermostats can be used to control conventional, heat pump, or multistage …


Honeywell CECOMINOD032202 FBA C7735A1000, Gray : …

out of 5 stars Addressed a failed duct air (DATS) sensor that prevented AC from turning on. Reviewed in the United States on February 12, 2019. Verified Purchase. This is an easy DIY fix. I saved a few hundred bucks too avoiding an overpriced HVAC service call. My issue was the three thermostats on my 3year old multizoned AC system were all calling for cool air but the compressor was not ...


Honeywell C7735A1000 ZONE MAX SENSOR

Mount on return duct for backup control of nonzoned systems. Dimensions (in.) 3 7/8 in. high x 4 1/8 in. wide x 1 1/4 in. deep. Dimensions (mm) 77 mm high x 102 mm wide x 25 mm deep. Sensor probe is 3 3/4 in. long (77 mm) Used With. THM5320R1000 Equipment Interface Module; TH6320R1004 or TH5320R1002 Wireless FocusPRO® Thermostat.


Honeywell C7735A1000 User Manual

C7735A1000 DISCHARGE AIR TEMPERATURE SENSOR. 2. Drill a 1/4 in. hole in the duct at the location selected for the sensor. 3. Remove the cover from the DATS case and insert the probe into the hole drilled in step 2. 4. Secure the DATS to the side of the duct, through the two mounting holes in the back of the case, with the screws supplied.


: Honeywell CECOMINOD032202 FBA …

Product Number: C7735A1000 DISCHARGE AIR TEMPERATURE SENSOR REPLACES ZM Category: HVAC Free Shipping on this item! › ... (DATS) sensor that prevented AC from turning on. Reviewed in the United States on February 12, 2019. Verified Purchase. This is an easy DIY fix. I saved a few hundred bucks too avoiding an overpriced HVAC service call. My issue was the three thermostats on …


691521EFS 01 C7735A1000 Duct Air Temperature Sensor

C7735A1000 Duct Air Temperature Sensor APPLICATION The C7735A1000 Duct Air Temperature Sensor (DATS) is a ductmounted temperature probe used to sense discharge air temperature in zoning applications for high and low temperature limit protection. Alternatively, it is used with certain Honeywell thermostats for deltaT diagnostics and IAQ control. For more on these applications, please see the ...


Honeywell HomeResideo RedLINK Duct Air Temperature ...

The Honeywell C7735A1000 DATS Sensor is heat pump compatible. It requires 2 wires to connect to the zone board. LED Indicator. Requires 2 wires to connect to the zone board. Product Weight. In most cases, it''s a simple issue that can be resolved over the phone.


C7735A1000 Temperature Sensor, Discharge Air for Use w/EIM ...

C7735A1000 MFG : C7735A1000. Buyer STOR ; Brand Honeywell ; Category Airflow Sensor ; Honeywell International Inc. / Resideo Technologies, Inc. 41/8" x 11/4" x 37/8", 0 to 200 Deg F, Return Duct Mount, Return Air Sensor Features Benefits. Works with THM5320R1000 Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat ; Takes control …


C7735A1000 Discharge Air Temperature Sensor

C7735A1000 Discharge Air Temperature Sensor APPLICATION The C7735A1000 Discharge Air Temperature Sensor (DATS) is a ductmounted temperature probe that provides capacity control of heating and cooling equipment. The DATS is used only with zoning solutions, including TZ3, MABS EZ2 and MABS EZ4, and EMM3 and EMM3U control panels. Mounted in the supply air duct, the DATS …


Honeywell C7735A1000 TROUBLESHOOTING

honeywell c7735a1000 troubleshooting . c7735a1000 discharge air temperature sensor, troubleshooting, c7735a1000 discharge air temperature sensor, or


Zone Panel Professional Installation Guide

Temperature Sensor (DATS)* DATS C7735A1000* SDCR Slave Damper Control Relay * Included in HZ221K kit. Installation Guide 692200—0 2 692200—0 iNsTallaTiON Mount the HZ221 TrueZONE panel near the HVAC equipment; locate it on a wall, stud, roof truss, or coldair return. NOTE: DUCTThe HZ221 TrueZONE panel can be mounted in any orientation; level it for appearance only. 1 DATS …


Honeywell C7735A1000 Duct Air Temperature Sensor

The Honeywell C7735A1000 Duct Air Temperature Sensor is a ductmounted temperature probe that provides capacity control of your HVAC equipment. Also known as a discharge air temperature sensor (DATS) it is only used with zoning solutions that include TZ3, EMM3 and EMM3U control panels. It senses the delivered air temperature and cuts off the heating or cooling when the delivered air ...


Honeywell Discharge Air Temperature Sensor (DATS ...

The Honeywell discharge air temperature sensor (DATS) is a duct mounted temperature probe that provides capacity control of heating and cooling equipment. The DATS is used only with zoning solutions such as Honeywell zone boards EMM3U, TZ4, and True Zone Panels. Mounted in the supply air duct, the DATS senses the delivered air temperature and cuts off the heating or cooling when the delivered ...


Discharge Air Temperature Sensor ...

10/12/2010· Hi everybody, I just got a Honeywell C7735A1000 discharge air temperature sensor from ebay. The description was that it was brand new, but it didn''t include a manual, mounting screws, or wire nuts, which the online manual specifically says is supplied. However, I don''t want to return it if that''s all that is missing. This is a picture of what I got. Is that all it is; a 32005180001 thermistor ...


C7735a1000 Community Forums

12/12/2010· C7735a1000. I just got a Honeywell C7735A1000 discharge air temperature sensor from ebay. The description was that it was brand new, but it didn''t include a manual, mounting screws, or wire nuts, which the online manual specifically says is supplied. However, I don''t want to return it if that''s all that is missing. This is a picture of what I got.


691521EFS 03 C7735A1000 Duct Air Temperature Sensor

C7735A1000 Duct Air Temperature Sensor APPLICATION The C7735A1000 Duct Air Temperature Sensor (DATS) is a ductmounted temperature probe used to sense discharge air temperature in zoning applications for high and low temperature limit protection. Alternatively, it is used with certain thermostats for deltaT diagnostics and IAQ control. For more on these applications, please see the ...


69219905 HZ322 TrueZONE Honeywell

C7735A1000 M28024 SENSOR DATS DATS 8 Connect a dedicated transformer as shown. DEDICATED TRANSFORMER R C M24806 R POWER C L1 (HOT) L2 RH RC W1/E W2 Y1 Y2 G O B DS/BK M28025 HVAC FAN RELAY 24 VOLT TRANS. G Y Y2 C R W COMPRESSOR RELAY W2 EQUIPMENT WIRING Fig. 7 Fig. 8 Fig. 10 7 When a wireless thermostat, Portable Comfort Control, …


Honeywell C7735A1000 Discharge Air Temperature Sensor ...

Honeywell C7735A1000 Discharge Air Temperature Sensor. Mount on return duct for backup control of nonzoned RedLINK™ enabled Wireless Systems and Thermostats. • Works with THM5320R1000 Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat. • Takes control of the equipment by turning on ...